KANE9206 QUINTOX

- Emissions Monitoring Solution

KANE9206 QUINTOX

- Emissions Monitoring Solution

  • Test boilers with stack draught over 50 mbar with high suction pump
  • Long term unattended testing with 64,000 test memory, remote handset & large graphic display
  • Unique 5 gas sensor technology
    • O2 0-21%
    • CO 0-10,000ppm H2 compensated
    • CO 0-10%
    • HC 0-5000ppm
    • CO2 0-20%
  • Option for 4 toxic sensors
  • Perform unattended boiler commissioning tests with automatic fresh air purge and optional WTS9206P automatic water trap
  • Perform MCERTS (pending) compatible emissions tests with optional gas conditioning unit, heated line & probe
  • Perform cold condition tests with optional KHSA sensor heater

Features

  • Large Graphic Display with 15 lines of text & data
  • Optional Gas Conditioning Unit for accurate NO2 & SO2 measurement
  • Wireless & cable link between Analyser & Handset for remote monitoring
  • Wireless & USB link to PC
    • Use KANE LIVE software for "real time" monitoring or test results transfer to a PC, tablet or smartphone
  • Large internal memory to store up to 64,000 tests
  • Main Purge
    • Zero & refresh sensors without removing probe from flue
    • Automatic sensor 'over range' protection
  • Integral printer & option to use KANE-IRP3
  • Heavy duty case protects analyser & handset - total weight: 9.5kg
  • 10 year warranty under KANE CARE Service & Recertification - our promise to never let you down or your money back

Sensor options - up to 4

  • KH2S/Q H2S 0-1000ppm sensor*
  • KNO1H/Q NO 0-5000ppm sensor
  • KNO2/Q NO2 0-1000ppm sensor*
  • KSO2H/Q SO2 0-5000ppm sensor*

Probe & accessory options

  • CHSLP6 1m high temperature PTFE lined smoke probe with removable shaft & 4m neoprene hose
  • KMCE10 10m hose & thermocouple extension
  • KHSA Toxic Sensors Heater
  • WTS9206P Automatic emptying water trap - not needed with KANE-GCU9206
  • KMDM* Gas conditioning unit & Automatic water trap
  • KMHL3000* 3m Heated Line to 120°C
  • KMHP1200* 1m Heated Probe to 120°C

Marine Engine Emissions Testing

  • Use all * items to measure NO2, SO2 & H2S - specify 110 / 230 voltage

For more information

give us a call on:

: 0800 059 0800

Measures

(Standard Kit)

  • O2 0-25%
  • CO2 0-21%
  • CO 0-10,000ppm H2 Compensated & 10% NDIR
  • HC 0-5,000ppm
  • Flue Temp 0-1100°C
  • Pressure 0-150 mbar

Calculates

  • CO2 (calculated) 0-20%

Fuel Types

  • Natural Gas (x2)
  • Town Gas
  • Anthracite
  • Wood Pellets
  • Bio Gas
  • LPG
  • Kinsale Gas
  • Gascor
  • Butane
  • Heavy oil / 35 sec
  • Propane
  • Coke
  • LPG
  • User fuel (x5)
  • Light oil / 28 sec
  • Coal

Box Contents

  • Supplied with remote handset, pressure connectors, PTFE lined CHSP6 probe, CL5 USB Lead, 19603 charger & heavy duty case

Videos

How to change graphs - KANE LIVE

How to change parameters - KANE LIVE

How to change user details - KANE LIVE

How to change viewable readings - KANE LIVE

How to connect supported bluetooth - KANE LIVE

How to download logs - KANE LIVE

How to pair and connect the QUINTOX - KANE LIVE

How to save data - KANE LIVE

How to use change the language - KANE LIVE

How to use help - KANE LIVE

How to use the pump functions - KANE LIVE

Service Price

YEAR 1 YEAR 2 YEAR 3 YEAR 4 YEAR 5
£360 £360 £360 £360 £540

Calibration or Conformity Certificates included, as appropriate

All prices £ GBP, exclusive of VAT & subject to change.

All prices are in £ sterling and are exclusive of VAT.

Software

Install

USB Serial Driver (Microchip)

Install

KANE LIVE

Install

KANE Live (Android app)

Manuals

KANE9206 Manual

KANE9206 Manual

KANE9206 Manual

Please register your analyser or sign in to download the manual.

Register Analyser